The article says: If any of these readings are outside limits, replace motor. It could also be a bad capacitor, which is like a battery, to start the motor. Holes in grids, or stitching coming apart Hi Robin, an F5 code? hayward blue essence troubleshootingautodrive microfiber towels. Let it sit overnight . If you see no gears moving, the timer motor may be dead. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
My client thinks the motor was 1hp, but he really not sure. Gail, good luck! I just replaced my pool pump motor because it was really loud and i figured it was the bearings. Follow disassembly/assembly procedures (pages 32 -37). Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. Anyone else have a scientific explanation? Davy, after going back into the pump again, i have come to the conclusion that the bearings are going out in the motor. Missing air bleeder sock or strainer cap Removed pump from housing- nothing in impeller spins freely. Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. Would the lack of enough sand cause the water to gush out of the top of the filter? I have mud in my filter so I guess I have a underground broken pipe. Electrician was here at least 4 times and did not find anything. Examine your pumps impeller for any obstructions, and replace the capacitor if necessary. Probably not your pump basket being full causing this but improper air flow caused by debris/dust. Occasionally, while running, it trips the breaker. This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. If there is an external 2-speed timeclock, check the wiring, esp. Good news.not really. Finally, if the new superpump is larger than the old one, the amperage draw may be too much for the breaker. dont know if the pump went bad already. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. It leaks from the impeler case and is noisey, so assy B is no replacement. Why would the pump and Polaris stop working at the same time? you can keep running it, while you get parts sure. Diagrams, Pool They function as the starting battery for the motor, to help it get up to speed quickly. If the switch does not close after the blower starts the control will go into lockout with the blower running. Im losing my mind. Not usually related to a tripped GFI, but I suppose they could be linked. Sparking can also come directly from a short in the windings of the motor. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Came out tonight and flipped the switch and pump started. Flush out the housing to clear debris, then refill with water. We have tried switching outlets and that sometimes works. Would this make the breaker flip? Is there a thicker housing oring that could be installed to fix the leak? Vacuum hose air leaks from splits in an old hose. A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? Can I replace a specific part or do I have to buy a new one? What is the problem. Just bought a hayward super II pump. When you see a quick spurt or spray of water when the pump shuts off, this is an area where air is entering the system, and causing priming problems. If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. If not, then it will usually be a bad capacitor, or start capacitor, located at 9 oclock, in the rear, a black cylinder. Not sure what to call it voltage selector perhaps? Inspect the motor for any burns evident on the casing as many times, an overheating motor will be shorted across the windings, and will soon fail. All check ok. everything works well but the circulation is half as strong as my last pump.Tried everything,BACKWASH,checked for air leaks. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. thanks. That is usually suitable, but 20 amp could also be used. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. I have been getting GFI breaker trips intermittently. Thanks for the comment, impellers dont normally wear out, they either work or they are flat busted and dont work. I am a novice with in ground pools, but is the pool motor supposed to run continuously? Also keep in mind that 1 lb of DE powder is not 16 oz of kitchen dry measure, but actually 32 oz (4 cups) of kitchen measure, because DE is so light and fluffy The normal unit of measure for 1 lb of DE powder is a 1 lb coffee can (or 4 8 oz cups). It could also be a loose switch in the back of the motor. my two speed Hayword pump clicks when Commonly appears on drain plugs, pump lids, pipe that screws into pump, or on incoming valves, like your Jandy. My wear ring fits very loosely and it seems like impeller shaft has worn down. It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. We have parts for the Super pump. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. Similar pumps, with the same flow rate characteristics, are not less expensive. Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. Armstrong Human Resource Management 13th Edition Pdf, If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Bobby, yes that would rule out the power source, or the outlet as being the problem. IE9 and older versions are not supported. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. It is only a 2-3 year old pump. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. Recently I started getting a loud vibration hum from my hayward pump. Clean Gasket (no bits of debris or de powder), 2. We have a sand filter and no pressure gage. Automatic restart is 2 minutes after the error is corrected. 1.5 horse power. There could also be a short in the wiring to the pump, or from the breaker to the switch. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. Reinstalled Same problem recycled power. Hi William, yes an air leak, is what I call it. They are cheap and easy to replace. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. Once I get it going, it works fine for as long as I leave it on. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. 4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking Thinking its the compressor or really dont know at this point. What can I do? The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. If you are comfortable using a power meter, you can measure power at all these points, breaker, timer or switch, and motor. The shaft turned with zero resistance. Remove all of the bolts around the top and pull out the Filter Nest, or all of the fingers. Motor was only humming. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Hey buddy. Ok I switched out the capacitor and it started up and ran for about 5 second and then blew the capacitor. Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. For the clamp band, yes the washer with the slightly smaller hole I.D. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. The third thing to check would be an obstruction on the pressure side of the pump, clogged impeller, clogged filter, closed return side valves or plugs in the wall. The new one is doing the same thing. However it is not generating enough chlorine and we are adding chlorine more than we should. You could take the motor or pump into an electrical motor shop for confirmation. The 2 bolts connecting it to the platform just turn and turn and go nowhere. Is this a new or older installation? Additional causes for low water flow in your pump are debris build-up or dirty equipment. Thanks. If they are within range, replace drive. Gas pressure is ok. Any ideas? please help. I checked the prong connector and found no juice there. Any suggestions? Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. Hi, my pump has power and makes no noise. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. Hi William, the on/off switch is sold as an entire end-cap piece, including the rear cover, the yellow wire would not be a part that is sold, I suppose you could make it yourself ? The pump then ran fine for about 10 minutes and then stopped working again. Hi Dave, check the owners manual to be sure that the cord size used is proper for the motor, and the plug, is a 3-prong grounded plug? Or third, it could be low voltage or a bad power cord, or loose power wire connections, or broken wires. Inspect for any damage to wires or wire casing. "@type": "Person",
. Is there a trick to this? Calling the pool builder for warranty info, too. Got another one, it too is doing the same thing. Hayward should be able to help, http://www.haywardnet.com see for contact info. Plunger was a good idea, a Drain King can also be used, from the pump, to blow debris back to the skimmer. While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. You could also use a Hayward 24 sand filter, item E3324. I have a Hayward super pump every once in awhile when I go to unplug to backwash it sparks and trips the breaker. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. See page 40/41 in this Hayward Troubleshooting guide. I just want to clarify..we had a problem with the fuse box and its just been changed. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. Hi Paul, could it be vibration noise? 2 year warranty. Products, Learn About You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. Or very high mineral content (very hard water), or oily substances. Or backwash extra long, 4-5 minutes. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! If it does, check power inside of the back of the motor, with a test meter. Have a brand new Hayward power flo LX. Make sure that there are no blockages in the impeller because the motor will not turn if the impeller cannot rotate. Hi Davy, spun and is loosely spinning. Hi Davy, After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. You can buy replacement drives I believe, that may be the (expensive) cure for the problem. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. I presume Ill be looking at buying a new pump next year. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. To fix the problem, manually reset the Inspect Cell LED. 3200 ppm is the ideal level. Nothing seems to give it juice. I have an aboveground kayak saltwater system . "height": "219",
Step 1: With your pump running, double-check the positions of your valves. If the meter reads zero, and stays at zero the capacitor is bad. I backwashed and started again and it was good for another 24 hours and the circulation stopped again and the pressure reached max. The salt cylinder is clean. If not, the parts internally, some parts, need replacement. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. For a better experience, please enable JavaScript in your browser before proceeding. I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. Lube should not be the issue with the leak, not required. Hi, thats strange! My issue is that the normal operating pressure is around 13-15 psi. Reattach capacitor, replace rear cover and test motor again. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. What should I do? Hi Tammy, could be many things. After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. This pump is not even a year old. Could also be a clog in the pipe. what do you think the hum could be? New pump, was running fine. Hayward Blue Essence Troubleshooting, Pool Supplies Near Me Open Now, Breville Tamper Coffee Kit 54mm, Used Cozzia Massage Chair, Power Pole Distribution Block, Signature Custom Cabinetry, hayward blue essence troubleshootinghi-c orange lavaburst bottle hayward blue essence troubleshooting Destacado beach outfit ideas for chubby Two going bad? It is brand new. All the electrical connections seem tight. otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. This usually means the motor needs to be replaced. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). I swapped the pump assembly with an almost identical Hayward that I found in the garage (bonus!) I also tried it in a different place same outcome.What am I doing wrong? Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. We purchased a Hayward Pump SP3220EE and I need to know how Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. "publisher": {
Cleaners will remove the grease/oils, and acid will remove scale deposits. Is this normal or is there a malfunction? We dont have mechanical time clocksit is all digital. They are easily replaceable. Hi David, impellers that have signs of wear are usually operating without a problem. 3 things are key, 1. The post-purge cycle will be completed once the blower prover switch closes. Thanks. Hi Rob, I think its a one-year warranty? What should i do now? Could this be an issue with my pump? Guess it is time for a new drive. It worked when fine for a couple of times but only clicks now. And check that incoming power matches the voltage for the motor, as the motor can be switched to accept 110V or 220V, see wiring diagram on motor label. This year I have developed a leak under the pump housing I believe. It does this everyday and then starts working like normaly for the rest of the day. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. 14 x 28 inground, water clear. This is my first pool. You are also using the diffuser? Hi Carolyn, yes either the thermostat or other temp sensor, if present, would be responsible for that symptom. Wire size inside socket too small (cant carry the current).
Mark Lawrenson Football Predictions This Weekend,
Waste Management Vs Republic Services Cost,
Example Of Pre Industrial Age Media,
Pa Wrestling Rankings 2022 Aaa,
Articles H